Electrical Specifications |
| |
Output power |
|
400 watts |
| |
Surge rating (5 seconds) |
|
800 watts |
| |
Output current (peak) |
|
10A |
| |
Output voltage (at no load) |
|
120 VAC -/+3 V |
| |
Output voltage (over full load and battery voltage range) |
|
120 VAC RMS -/+5 V |
| |
Output frequency |
|
60.0 -/+ 0.05 Hz |
| |
Output waveform |
|
Sine wave (<3% THD) |
| |
Peak efficiency |
|
0.88 |
| |
No load power draw |
|
<15 W |
| |
Power draw in standby mode |
|
0 watts |
| |
Input operating voltage range |
|
10.3 - 15.3 VDC |
| |
Transfer relay rating |
|
6A |
| |
General Specifications |
| |
Operating temperature range |
|
32°F - 104°F (0°C - 40°C), derated linearly to 300 watts at 122°F (50°C) |
| |
Storage temperature range |
|
-22°F - 158°F (-30°C - 70°C) |
| |
AC receptacle |
|
Dual, three-prong GFCI receptacle and hardwire on front of unit |
| |
Recommended DC fuse |
|
80 A |
| |
Dimensions (HxWxD) |
|
3.7 x 7.4 x 13.5” (83 x 187 x 343 mm) |
| |
Weight |
|
10.0 lb (4.6 kg) |
| |
Remote switch |
|
Included with unit (808-2400) |
| |
Part numbers |
|
806-0400 Single unit packaging (1 per box) |
| |
|
|
|
| |
Regulatory Approvals |
| |
CSA/NRTL certified to UL 458 and CSA C22.2 No. 107.1 |
| |
EMC: FCC Class B |
| |
| Note: Specifications subject to change without notice. |