Home Products Support Buy Company Contacts
English Deutsch Français Italiano Español Korean
 
[Enlarge Image]

 
 
XDC Series - 6 kW and 12 kW

XDC provides clean, reliable power for benchtop, ATE systems, burn-in, production test and OEM applications.

 
Product Info | Specifications | Compare
 
Specifications Available

6 kW 10-600
6 kW 20-300
6 kW 30-200
6 kW 40-150
6 kW 60-100
6 kW 80-75
6 kW 100-60
6 kW 150-40
6 kW 300-20
6 kW 600-10
12 kW 10-1200
12 kW 20-600
12 kW 30-400
12 kW 40-300
12 kW 60-200
12 kW 80-150
12 kW 100-120
12 kW 150-80
12 kW 300-40
12 kW 600-20

6 kW 80-75

  Electrical Specifications
  Output ratings:    
  Output Voltage 1   0-80 V
  Output Current 2   0-75 A
  Output Power   6000 W
  Line Regulation: 3    
  Voltage (0.01% of Vmax)   3 mV
  Current (0.05% of Imax)   20 mA
  Load regulation: 4    
  Voltage (0.05% of Vmax + 5 mV)   10 mV
  Current (0.1% of Imax + 20 mA)   20 mA
  Meter accuracy:    
  Voltage (0.15% of Vmax)   120 mV
  Current (0.5% of Imax)   375 mA
  Output noise (0-20 MHz):    
  Voltage (p-p)   75 mV
  Output ripple (rms):    
  Voltage   12 mV
  Current 5   30 mA
  Drift (30 minutes): 6    
  Voltage (0.04% of Vmax)   32 mV
  Current (0.6% of Imax)   450 mA
  Drift (8 hours): 7    
  Voltage (0.02% of Vmax)   16 mV
  Current (0.04% of Imax)   30 mA
  Temperature coefficient: 8    
  Voltage (0.04% of Vmax/° C)   32 mV
  Current (0.06% of Imax/° C)   45 mA
  OVP adjustment range: (0 to 103% of Vmax)   0-82.4 V
  Efficiency: 9   89%
       
  1. Minimum output voltage is <0.3% of rated voltage at zero output setting.
  2. Minimum output current is <0.2% of rated current at zero output setting when measured with rated load resistance.
  3. For input voltage variation over the AC input voltage range, with constant rated load.
  4. For 0-100% load variation, with constant nominal line voltage.
  5. Current mode noise is measured from 10% to 100% of rated output voltage, full current, unit in CC mode.
  6. Maximum drift over 30 minutes with constant line, load, and temperature, after power on.
  7. Maximum drift over 8 hours with constant line, load and temperature, after 30 minutes warm-up.
  8. Change in output per ° C change in ambient temperature, with constant line and load.
  9. Typical efficiency at nominal input voltage and full output power.
   
  General Specifications
  Operational AC input voltage   3-phase 190-242 VAC (47-63 Hz) (standard); 3-phase 342-500 VAC, 47-63 Hz, 3 wire and safety ground, (optional)
  Input Power Factor Correction   0.95 (nominal 208 Vrms), 0.9 (nominal 400 Vrms HV input option)
  Remote analog programming   Voltage and current programming inputs; 0-5 V, 0-10 V (default) voltage sources. Galvanically isolated from supply output.
  Remote analog monitoring   Voltage and current monitor outputs 0-5 V, 0-10 V (default) ranges for 0-100% of output. Galvanically isolated from supply output.
  Dimensions (H x W x D)   5.2 x 19.0 x 21.0" (133.5 x 483 x 533 mm)
  Weight   Approximately 75 lb (34 kg)
  Warranty   Five years
  Regulatory Approvals
 

CE-marked units meet: EN61010-1, EN61000-6-2 and EN61000-6-4; CSA C/US certified to UL3111-1 and CSA C22.2 No 1010.1
Meets USA EMC standard: FCC, part 15B, class A; Meets Canadian EMC standard: ICES-001 Class A.

 
Note: Specifications subject to change without notice.
 
   
   
 
     
 Web Site Terms & Conditions
©2000 - 2009 Xantrex Technology Inc.