Electrical Specifications |
|
|
Voltage Configurations |
|
12 and 24 VDC |
|
|
Max. PV Open Circuit Array Voltage |
|
55 VDC |
|
|
Charging / Load Current (at 25 °C) |
|
60 amps DC |
|
|
Max. Peak current |
|
85 amps |
|
|
Max. Voltage Drop through Controller |
|
0.30 volts |
|
|
Typical Operating Consumption |
|
15 ma |
|
|
Typical Idle Consumption |
|
3 ma |
|
|
Recommended Breaker Size |
|
60 amps rated at 1000% continuous duty |
|
|
Recommended Wire Size |
|
#6 AWG rated at 90 °C |
|
|
Lead Acid Battery Settings |
|
Adjustable |
|
|
NiCad Battery Settings |
|
Adjustable |
|
|
Load Control Mode |
|
Low Voltage Reconnect - Adjustable (sticker provided with unit) all models |
|
|
|
|
Low Voltage Disconnect - User selectable manual or automatic reconnection - includes warning flash before disconnect and provides a one time, user selectable grace period) all models |
|
|
General Specifications |
|
|
Specified Temperature Range |
|
32° F to 104° F (0° C to 40° C) |
|
|
Enclosure Type |
|
Indoor, ventilated, powder coated steel with 3/4" and 1" knockouts |
|
|
Unit Weight |
|
|
|
|
Shipping Weight |
|
|
|
|
Dimensions (H x W x D) |
|
|
|
|
Shipping Dimensions (H x W x D) |
|
|
|
|
Mounting |
|
Vertical wall mount - indoor only |
|
|
Altitude - Operating |
|
15,000' (4,572 m) |
|
|
Altitude - Non-Operating |
|
50,000' (15,240 m) |
|
|
Warranty |
|
Two years |
|
|
Part Numbers |
|
C5, C40, C60 - Controllers |
|
|
|
|
CM - Front Display Panel |
|
|
|
|
CM/R-50, CM/R-100 - Remote Display Panel |
|
|
|
|
BTS - Battery temperature sensor |
|
|
Features & Options |
|
|
Regulation Method |
|
Solid stage, three-stage (bulk, absorption, and float), pulse width modulation |
|
|
Field Adjustable Control Setpoints |
|
Two user adjustable voltage setpoints for control of loads or charging sources - setting retained if battery is disconnected |
|
|
Display Panel |
|
CM, CM/R-50, or CM/R-100 - optional LCD - backlit, alphanumeric display showing battery voltage, DC amperage, cumulative amp hours, and amp hours since last reset - remote includes 50' (15 m) or 100' (30.5 m) cable |
|
|
Equalization Charge |
|
User selectable manual or automatic equalization - every 30 days |
|
|
Battery Temperature Sensor |
|
BTS - optional remote battery temperature sensor for increased charging precision |
|
|
Regulatory Approvals |
|
|
UL Listed to UL 1741 - 1999 and to CSA 22.2 No. 107.1-95 Standards, CE compliant |
|
|
|