C12

The C12 has a LED status light displaying both charging functions and battery charge state at a glance. This controller is used worldwide in a variety of applications.

 
Product Info | Specifications | Document Downloads | Compare | List Price
 
Specifications Available

Specifications
Description 2

Specifications

 

Electrical Specifications

 

PV Amps (Max.)

 

12 A at 12 VDC only

 

DC Load (Max.)

 

12 A with auto reset

 

Operating Voltage (Min.)

 

6 V

 

Voltage Drop - PV to Battery (Max.)

 

0.3 V

 

Voltage Drop - Battery to DC Load (Max.)

 

0.15 V

 

Regulation Setting

 

13 to 15 VDC

 

Equalize Setting

 

Bulk plus 1 V for two hours

 

Consumption while charging (typical)

 

0.007 A

 

Consumption at night (typical)

 

0.003 A

 

Consumption with load disconnected (typical)

 

0.003 A

 

Stranded wire size (Max.)

 

#10 AWG stranded (5.4 mm2)

 

General Specifications

 

Allowed Temperature Range

 

32° F to 104° F (0° C to 40° C)

 

Enclosure Type

 

Powder coated steel with strain relief for wiring and knockouts for up to three 1/2" conduits

 

Unit Weight

 

2 lb (0.9 kg)

 

Shipping Weight

 

2.5 lb (1.13 kg)

 

Dimensions (H x W x D)

 

6.25 x 4.3 x 1.5" (16.5 x 11 x 4 cm)

 

Shipping Dimensions (H x W X D)

 

8 x 4.6 x 1.6" (20.3 x 11.7 x 4 cm)

 

Mounting

 

Vertical wall mount - indoor

 

Warranty

 

Two years

 

Part Numbers

 

C12 - charge controller

 

 

 

BTS - optional battery temperature sensor

 

Features & Options

 

Regulation Method

 

Standard - three stage (bulk, absorption and float), solid state, pulse width modulation

 

Field Adjustable Control Setpoints

 

Standard - removable knobs and calibrated scales

 

Setting Protection

 

Standard - knobs can be removed to prevent tampering

 

Testpoints

 

Standard - provided for each setting

 

Automatic Equalization

 

Standard - every 30 days or after voltage reaches low voltage disconnect - can be disabled

 

External Battery Temperature Compensation

 

Optional - battery temperature sensor (BTS)

 

Short Circuit Protection

 

Standard - fully electronically protected with auto reset and manual reset switch, protects both the loads and PV array from damage from short circuits - a fuse for the battery is still advised to protect the battery wires if located separately

 

Reverse Polarity Protection

 

Standard - fully protected

 

Low Voltage Disconnect

 

Standard - adjustable automatic or manual operation, manual reconnection includes warning flash of loads five minutes before and ten minutes grace period

 

 

 

 

 

Note: Specifications subject to change without notice.

 

 
   
   
 
     