Electrical Specifications |
|
|
AC input voltage |
|
120 VAC |
|
|
AC input voltage range |
|
80 - 149 VAC |
|
|
AC input current |
|
60 amps AC pass thru 30 amps AC charging (Required for full pass through and full charging) |
|
|
Continuous Power @ 25°C |
|
2500 VA |
|
|
Efficiency (Peak) |
|
90% |
|
|
AC output voltage (RMS) |
|
120 VAC |
|
|
AC output voltage regulation |
|
+/- 5% |
|
|
Frequency |
|
60 Hz |
|
|
Waveform |
|
Sine wave, 34 - 52 steps per cycle |
|
|
Total harmonic distortion |
|
< 5% |
|
|
Continuous output @ 25°C |
|
21 amps AC |
|
|
Surge capability: |
|
|
|
|
5 sec rating (resistive) |
|
4000 watts |
|
|
1 mSec |
|
65 amps AC |
|
|
100 mSec |
|
46 amps AC |
|
|
Automatic transfer relay |
|
60 amps |
|
|
DC input voltage (Nominal) |
|
12 VDC |
|
|
DC input voltage range |
|
11.8 - 16.5 VDC |
|
|
DC current at rated power |
|
275 amps |
|
|
Idle consumption |
|
< 16 watts Typical at Full Voltage |
|
|
Search mode consumption |
|
< 1 watt |
|
|
Max. charge rate (adjustable) |
|
150 amps DC at 12 V nom. |
|
|
General Specifications |
|
|
Specified temperature range |
|
32°F - 77°F (0°C - 25°C) Power derated about 25°C |
|
|
Enclosure type |
|
Indoor, ventilated, steel chassis with powdercoat finish |
|
|
Unit weight |
|
90 lb (41 kg) |
|
|
Shipping |
|
96 lb (45 kg) |
|
|
Inverter dimensions (H x W x D) |
|
15 x 22.5 x 9" (38 x 57 x 23 cm) |
|
|
Shipping dimensions (H x W x D) |
|
15 x 27 x 21" (38 x 69 x 53 cm) |
|
|
Mounting |
|
Bulkhead mount |
|
|
Warranty |
|
Two years |
|
|
Part numbers |
|
SW2512MC |
|
|
|
|
SW4024MC2 |
|
|
|
|
SWRC (SW remote control panel with LCD and 25' cable for SW4024MC2 and SW2512MC) |
|
|
|
|
SWRC/50FT (same as above but with 50' cable) |
|
|
Regulatory Approvals |
|
|
cETL approved to UL 1741, UL 458, and CSA 107.1 |
|
|
|
Note: Specifications subject to change without notice. |
|
|
|
|
|
|
|