Electrical Specifications |
|
|
AC Input Voltage (nominal) |
|
120 VAC |
|
|
AC Input Voltage Range, adjustable |
|
80-150 VAC |
|
|
AC Input Current |
|
60 amps AC pass through / 20 amps AC charging |
|
|
Continuous Power @ 40°C |
|
2500 watts |
|
|
Efficiency (peak in Inverter mode) |
|
95% |
|
|
Efficiency (Invert mode) |
|
Over 90% from 160W to 2500W |
|
|
Inverter Voltage Regulation |
|
+/- 3% |
|
|
Frequency (Nominal +/- 0.04% crystal controlled) Inverter mode |
|
60 Hz |
|
|
Continuous Output Current @ 25°C |
|
21 A rms |
|
|
Current Surge Capability @ 25°C: |
|
|
|
|
5 sec rating |
|
80 A rms |
|
|
Over current trip point |
|
175 A peak |
|
|
Inverter Voltage THD (Resistive load) |
|
< 5% |
|
|
Automatic Transfer Relay |
|
60 A rms |
|
|
DC Input Voltage (Nominal) |
|
50.4 VDC |
|
|
DC Input Voltage Range |
|
44-64 VDC |
|
|
DC Current at Rated Power (Inverter mode), internal temperature stabilized |
|
60 amps DC |
|
|
Idle Consumption (Typical at full voltage) |
|
< 20 watts |
|
|
Search Mode Consumption (Typical at full voltage) |
|
< 2 watts |
|
|
Continuous Charge Rate @ 120 VAC input (See Note 1 below) |
|
40 amps DC |
|
|
Mechanical Specifications |
|
|
Operating Temperature Range: |
|
|
|
|
Unit will meet specifications |
|
32°F - 77°F (0°C - 25°C) |
|
|
Unit may not meet specifications |
|
-13°F - 140°F (-25°C - 60°C) |
|
|
Storage |
|
-67°F - 284°F (-55°C - 140°C) |
|
|
Enclosure Type |
|
Indoor, ventilated, Galvaneel chassis with powdercoat finish |
|
|
Unit Weight |
|
105 lb (48 kg) |
|
|
Shipping Weight |
|
111 lb (50 kg) |
|
|
Inverter Dimensions (H x W x D) |
|
15 x 22.5 x 9" (38 x 57 x 23 cm) |
|
|
Shipping Dimensions (H x W x D) |
|
20 x 27 x 15" (52 x 69 x 40 cm) |
|
|
Mounting |
|
Wall mount/Shelf |
|
|
Features |
|
|
Forced Air Cooling |
|
Standard variable speed brushless DC fans |
|
|
Multi-stage charging |
|
Bulk, absorption, float/silent, and equalize |
|
|
Control Panel |
|
Standard built-in, two line, backlit, alphanumeric LCD with 8 LED indicators |
|
|
Battery Temperature Sensor (BTS) |
|
BTS - standard remote battery temperature sensor for increased battery performance |
|
|
Options |
|
|
Generator Start Module (GSM) |
|
Automatic generator control system for two and three wire start AC and DC generators |
|
|
Auxiliary Load Module (ALM) |
|
User adjustable voltage controlled signal relays for control of loads or charging sources |
|
|
Remote Inverter Control Module (ICM) |
|
Optional full function remote control with LCD and LED indicators |
|
|
RC8 |
|
Optional remote on/off with indicator |
|
|
Stacking Interface (ISC-S) |
|
Optional cable for series of stacking of two identical SW Plus units for 120/240 VAC output |
|
|
DC Conduit Box (DCCB) |
|
Optional side mount conduit box for code-compliant DC wiring connections (USA) |
|
|
DC Conduit Box Fused (DCCB-F) |
|
Optional side mount conduit box for code-compliant DC wiring connections with fuse (Canada) |
|
|
AC Conduit Box (ACCB) |
|
Optional side mount conduit box for code-compliant AC wiring (bypass/disconnect circuit breakers) |
|
|
Common Specifications |
|
|
Waveform |
|
Sine wave, 34 to 52 steps per cycle |
|
|
Load Sensing (Inverter Mode) |
|
Adjustable 8 to 248 watts (8 watts default) |
|
|
Listings |
|
CSA listed to UL 1741 and CSA107.1 FCC Class B |
|
|
|
Note: Specifications subject to change without notice. |
|
|