Electrical Specifications |
|
| |
Nominal power rating (AC) |
|
29.9 kW |
|
| |
Nominal AC voltage |
|
400 V, 3~phase |
|
| |
Nominal AC frequency |
|
50-60 Hz |
|
| |
Line power factor |
|
> 0,99 obove 20% rated power |
|
| |
AC current distortion |
|
< 4% THD at rated power |
|
| |
Max input current (DC) |
|
77.4 Adc |
|
| |
Night consumption |
|
1 W |
|
| |
Min. DC voltage for feed-in |
|
450 Vdc |
|
| |
Suggested PV power |
|
25 to 35 kWp |
|
| |
Max continuous power (DC) |
|
32.9 kW |
|
| |
Max. open-circuit voltage (DC) |
|
840 Vdc |
|
| |
Power tracking window range |
|
450 to 800 V |
|
| |
Max efficiency |
|
95.0% incl. transformer |
|
| |
European efficiency |
|
94.2% incl. Transformer |
|
| |
General Specifications |
|
| |
Ambient temperatur range |
|
0 °C to +50 °C |
|
| |
Enclosure environmental rating |
|
IP20 (optional IP21) |
|
| |
Enclosure |
|
Powder-coated aluminum |
|
| |
Weight |
|
80 kg |
|
| |
Dimensions |
|
710 x 475 x 347 mm |
|
| (H x W x D) |
| |
Relative humidity |
|
0 to 95%, non-condensating |
|
| |
Features & Options |
|
| |
Cooling method |
|
Temperature-dependent forced-convection cooling |
|
| |
Schutzfunktionen |
|
AC over/under voltage, AC over/under frequency, over-temperature, AC and DC over-current, DC over-voltage |
|
| and reverse-polarity protection |
| |
Bedien- und Anzeigeeinheit |
|
LCD, four-line text display with keypad |
|
| |
Erdschlussüberwachung |
|
DC isolation monitoring |
|
| |
Abschaltvorrichtungen |
|
AC contactor integral to inverter assembly |
|
| |
Transformator |
|
HF - Transformer |
|
| |
Aufstellung / Installation |
|
Prepared for wall mounting |
|
| |
Meldekontakte |
|
Four relay contacts (three user-settable) |
|
| |
Datenkommunikation |
|
RS232/485, optional telephone modem for remote system monitoring |
|
| |
Combiner Box |
|
Optional feature − includes DC over-voltage protection and disconnect, calibrated AC power metering, string fusing and monitoring, |
|
| Weblog Pro and irradiance meter |
| |
Warranty |
|
Five years (extended warranties optional) |
|
| |
Approvals and Safety |
|
| |
Labeled with CE mark and complies with applicable European Directives: EMC Directive: EN50081-2, EN50082-2, Low Voltage Directive: EN50178; complies with the requirements of VDEW |
|
| |
|
|
|
|
|
|
| Note: Specifications subject to change without notice |
|