| Electrical Specifications |
|
|
|
| Supply voltage range |
9 to 35 Vdc |
| Supply current * |
|
| · @ Vin = 12 Vdc |
9 mA |
| · @ Vin = 24 Vdc |
7 mA |
| Input voltage range |
|
| · Main battery |
0 to 35 Vdc |
| · Auxiliary battery |
2 to 35 Vdc |
| Input current range** |
-999 to +999A |
| Battery capacity range |
20 to 999A |
| Readout resolution |
|
| · Voltage (0 to 35V) |
± 0.1V |
| · Current |
0 to 99A (± 0.1A) |
| · Current |
100 to 999A (± 1A) |
| · Amphours |
0 to 99Ah (± 0.1Ah) |
| · Amphours |
100 to 999Ah (± 1Ah) |
| · State-of-charge |
± 1% |
| Voltage measurement accuracy |
± 0.3% |
| Current measurement accuracy |
± 0.4% |
|
|
| General Specifications |
|
|
|
| Operating temperature*** |
-20 to 50°C |
| Battery monitor dimensions |
|
| · Front panel |
∅ 2.54” (64mm) |
| · Body diameter |
∅ 2.05” (52mm) |
| · Total depth |
∅ 3.11” (79mm) |
| Shunt dimensions |
|
| · Footprint |
1.77 x 3.43” (45 x 87mm) |
| · Height |
0.67” (17mm) base / 1.38” (35mm) terminal bolts |
| Weight |
|
| · Battery monitor weight |
0.21 lb (95 g) |
| · Shunt weight |
0.32 lb (145 g) |
| Warranty |
One year |
| Part Numbers |
84-2030-00 |
|
|
| Accessories |
|
|
|
| Connection kit - 50ft (15m) |
854-2021-01 |
|
|
| Regulatory & Environmental Compliance |
|
|
| EMC Directive 2004/108/EC (EN61000-6-2 and -6-3). Automotive EMC Directive 95/54/EC. RoHS Directive 2002/95/EC |
|
|
| * Measured with backlight and alarm relay turned off. |
| ** Only available when optional temperature sensor is connected. |
| *** Depends on selected shunt. With standard delivered 500A/50mV shunt (350A continuous), the range is limited from -600 to +600A. |
| Note: Specifications subject to change without notice. |