| Electrical Specifications - Inverter |
|
|
|
|
|
| Models |
HF 1000 |
HF 1800 |
|
|
|
| Output power (continuous) |
1000 W |
1800 W |
| Surge power |
2000 W |
3600 W |
| Output frequency regulation |
60 Hz |
60 Hz |
| Inverter voltage regulation |
115 +/-10 Vrms |
115 +/-10 Vrms |
| Output wave form |
Modified sine wave |
Modified sine wave |
| Efficiency (full load) |
> 82% |
> 82% |
| Peak efficiency |
> 87% |
> 87% |
| No-load current draw (idle mode) |
< 1 Adc |
< 1 Adc |
| Off mode current draw (display off) |
< 5 mA |
< 5 mA |
|
|
|
| Electrical Specifications - Charger |
|
|
| Charge rate |
20 A |
40 A |
| AC input voltage range |
95 – 130 Vac |
|
| AC transfer relay |
30 A |
30 A |
| Battery voltage (nominal) |
12 Vdc |
12 Vdc |
| Battery voltage range |
10.5 – 15.5 Vdc |
10.5 – 15.5 Vdc |
| Low battery cut-out |
10.5 Vdc |
10.5 Vdc |
| AC input (max. charge) |
5 Aac |
9 Aac |
| Default bulk charge voltage setting |
14.2 Vdc |
14.2 Vdc |
| Default float charge voltage setting |
13.5 Vdc |
13.5 Vdc |
| Equalize charge voltage (wet cell only) |
N/A |
N/A |
| Battery charge outputs |
One |
One |
| Charge control |
Three-stage |
Three-stage |
| Battery type settings |
Flooded / Gel / AGM / Fixed 13.5 Vdc |
| Equalization |
No |
No |
| Internal temperature-sensitive charging |
Yes |
Yes |
|
|
|
| General Specifications |
|
|
| Optimal operating temperature range |
32°F to 104°F (0°C to 40°C) |
|
| Optional remotes |
Detachable display |
Detachable display |
| Unit weight |
10 lb (4.5 kg) |
12.8 lb (5.8 kg) |
| Unit dimensions (H x W x L) |
4.2 x 9.5 x 15.5“ |
4.2 x 9.5 x 18.0“ |
| |
(106 x 241 x 393 mm) |
(106 x 241 x 457 mm) |
| Warranty |
One year |
One year |
| Part number |
806-1020 |
806-1840 |