Specifications
| Electrical Specifications (@ 25°C unless otherwise noted) |
| Models |
TRUECHARGE2 20 / 40 |
| Output current (nominal) |
20 A / 40 A |
| Output voltage (nominal, depending on settings) |
| Charge |
14.2 - 15.5 Vdc |
| Float |
13.4 - 13.8 Vdc |
| Equalize |
16 Vdc |
| DC output connections |
Three |
| AC input voltage 1 |
90-265 Vac 47-63 Hz |
| |
120 Vac, 230 Vac, 240 Vac nominal |
| Temperature compensation |
Three settings or optional remote battery temperature sensor |
| Charger efficiency |
> 80% |
| Battery type |
Gel, Flooded, AGM and Pb-Ca |
| Recommended battery size |
100 Ah to 400 Ah |
|
|
| General Specifications |
|
| Models |
TRUECHARGE2 20 / 40 |
| Operating temperature 2 |
0 to 65°C |
| Storage temperature |
-40 to 80°C |
| Battery connection |
Three positive terminals |
| |
One negative terminal |
| Dimensions (H x W x L) |
2.8 x 6.7 x 9.8” |
| |
(70 × 170 × 250mm) |
| Weight |
4.8 lb (2.2 kg) |
| Warranty |
Two year |
| Part Numbers |
804-1220 |
| |
804-1240 |
| |
|
| Remote Panel |
808-8040-00 |
| Battery Temperature Sensor |
808-0232-01 |
|
|
| Regulatory & Environmental Compliance |
CSA E60335-2-29, UL1564, and UL1236 including the Marine Supplement, drip test, and Ignition Protection ratings. CE Marked for the Low Voltage Directive
(safety) and the EMC Directive. Complies with IEC 60335-2-29 including Australian deviations. Ingress protection rating IP32 per EN/IEC 60529. Complies with FCC Part 15B and Industry Canada ICES-003 Class B emissions limits. Complies with ABYC A-31.
1 90 - 105 Vac ± 4 Vac output de-rated to 80% of full load current.
2 Between 50° and 65°C DC output current de-rated. Highly Accelerated Life Tested (HALT) to -20°C.
Note: Specifications subject to change without notice.
Three-Stage Charging
Multistage charging ensures batteries receive optimum charging, but with minimal wear and tear, regulating the voltage and current delivered to the batteries in three automatic stages:
- Bulk: Replaces 70-80% of the battery’s state-of-charge at the fastest possible rate.
- Absorption: Replenishes the remaining 20-30% of charge, bringing the battery to a full charge at a slow, safe rate.
- Float: Voltage is reduced and held constant in order to prevent damage and maintain batteries at a full charge.
Power Factor Corrected (PFC)
Less shorepower is required for charging batteries, freeing up more usable AC power for running electrical devices and appliances and reducing the likelihood of tripping shorepower breakers.