Specifications

Converter Specifications      
 
Model TRUECHARGE RV-40

TRUECHARGE RV-60

   TRUECHARGE RV-80
AC Input                                    
AC input current (at rated output) 6 Aac 9 Aac      12 Aac  
Nominal input voltage  120 Vac, 60 Hz    
Normal operating input voltage   108 Vac – 130 Vac    
Min. operating input voltage  90 Vac    
Max. operating input voltage 140 Vac    
Power factor (rated output, nominal input)   >= 0.95      
Safe (non-operating) input voltage range   0 – 150 Vrms    
Frequency   50 – 70 Hz     
DC Output                                                                                                                                                                                                    
Recommended maximum battery bank size   220 Ah    220 Ah      400 Ah
Output current   40 Adc    60 Adc      80 Adc
Current limit (maximum)   44A    64 A      84 A
Nominal output voltage 3.5 Vdc (float charge)     
  14.2 Vdc (bulk/absorption charge)    
Load regulation a 1.5% at terminals of TrueCharge RV    
Line regulation  b 1.50%    
No load voltage accuracy   0.1 Vdc     
Efficiency at nominal output   >= 85%      
Battery draw when turned off   < 2 mA      
Nominal temperature 30 °C    
Operating temperature range c 14 °F to 140 °F (-10 °C to 60 °C)     
Storage temperature range -4 °F to 176°F  (-20 °C to 80 °C)    
Dimensions (H x W x L) 4 3/4 x 7 1/8  x 11 13/16 “  (120 x 180 x 300 mm)  
Weight  7.9 lb (3.6 kg) 8.2 lb (3.7 kg)    8.3 lb (3.8 kg) 
Part Numbers                                
     OEM 4 pack 810-4012-00 810-6012-00    810-8012-00     
     Aftermarket/Service single pack 810-4012-10 810-6012-10    810-8012-10
(a) Line regulation is the converter’s ability to maintain a constant output voltage as the line (input) voltage changes.
(b) Load regulation is the converter’s ability to maintain a constant output voltage as the load current changes.
(c) Full ratings to 30 ˚C. Automatic output derating feature from 30 ˚C to 60 ˚C, above 60 ˚C unit may shut down. 
Panel Specifications      
       
Model 30 A AC/DC panel  50 A AC/DC panel   
AC fusing (Main) 1 x Cutler Hammer/ Bryant 2 x Cutler Hammer/ Bryant
Westinghouse Type BR Series Westinghouse Type BR Series
ITE Gould QP Series. ITE Gould QP Series. 
Max rating 30 A Max rating 25 A dual phase (ganged)
    50 A split phase  
AC fusing (Branch) 8 x Cutler Hammer/ Bryant  10 x Cutler Hammer/ Bryant/
Westinghouse Type BR Series Westinghouse Type BR Series
ITE Gould QP Series.  ITE Gould QP Series. 
Max rating 20 A Max rating 20 A
DC fusing 11 x Littelfuse Type 257 (or equivalent).   
  Max rating 20 A    
Operating temperature range 14 °F to 140 °F (-10 °C to 60 °C)     
Dimensions
Opening (stand alone) (H x W x D) 8 x 12 x 3 7/16” (203 x 305 x 87 mm)
Opening (with converter) (H x W x D) 12 1/8 x 12 x 4 3/4” (308 x 305 x 121 mm)
Face dimensions - Panel & Converter (cover on)         13 1/16 x 13 15/16” (332 x 354 mm)
Face dimensions - Panel only (cover on)                     13 1/16 x 8 13/16” (332 x 224 mm)    
Weight 3.5 lb ( (1.59 kg)    
Part numbers       
     OEM 4 pack 810-0030-00 810-0050-00  
     Aftermarket/Service single pack 810-0030-10 810-0050-10  
Regulatory Approvals 
UL458 (Panel board designed to meet UL67 when installed with converter) CSA C22.2 No. 107.1, FCC part 15B (Class B), ICES-0003 (Class B)
Note: Specifications subject to change without notice. 

 
   
   
 
     