| Converter Specifications |
|
|
|
| |
|
|
|
| Model |
TRUECHARGE RV-40 |
TRUECHARGE RV-60 |
TRUECHARGE RV-80 |
| AC Input |
|
|
|
| AC input current (at rated output) |
6 Aac |
9 Aac |
12 Aac |
| Nominal input voltage |
120 Vac, 60 Hz |
|
|
| Normal operating input voltage |
108 Vac – 130 Vac |
|
|
| Min. operating input voltage |
90 Vac |
|
|
| Max. operating input voltage |
140 Vac |
|
|
| Power factor (rated output, nominal input) |
>= 0.95 |
|
|
| Safe (non-operating) input voltage range |
0 – 150 Vrms |
|
|
| Frequency |
50 – 70 Hz |
|
|
| DC Output |
| Recommended maximum battery bank size |
220 Ah |
220 Ah |
400 Ah |
| Output current |
40 Adc |
60 Adc |
80 Adc |
| Current limit (maximum) |
44A |
64 A |
84 A |
| Nominal output voltage |
3.5 Vdc (float charge) |
|
|
| |
14.2 Vdc (bulk/absorption charge) |
|
|
| Load regulation a |
1.5% at terminals of TrueCharge RV |
|
|
| Line regulation b |
1.50% |
|
|
| No load voltage accuracy |
0.1 Vdc |
|
|
| Efficiency at nominal output |
>= 85% |
|
|
| Battery draw when turned off |
< 2 mA |
|
|
| Nominal temperature |
30 °C |
|
|
| Operating temperature range c |
14 °F to 140 °F (-10 °C to 60 °C) |
|
|
| Storage temperature range |
-4 °F to 176°F (-20 °C to 80 °C) |
|
|
| Dimensions (H x W x L) |
4 3/4 x 7 1/8 x 11 13/16 “ |
(120 x 180 x 300 mm) |
|
| Weight |
7.9 lb (3.6 kg) |
8.2 lb (3.7 kg) |
8.3 lb (3.8 kg) |
| Part Numbers |
|
|
|
| OEM 4 pack |
810-4012-00 |
810-6012-00 |
810-8012-00 |
| Aftermarket/Service single pack |
810-4012-10 |
810-6012-10 |
810-8012-10 |
|
|
|
|
| (a) Line regulation is the converter’s ability to maintain a constant output voltage as the line (input) voltage changes. |
| (b) Load regulation is the converter’s ability to maintain a constant output voltage as the load current changes. |
| (c) Full ratings to 30 ˚C. Automatic output derating feature from 30 ˚C to 60 ˚C, above 60 ˚C unit may shut down. |
|
|
|
|
| Panel Specifications |
|
|
|
| |
|
|
|
| Model |
30 A AC/DC panel |
50 A AC/DC panel |
|
| AC fusing (Main) |
1 x Cutler Hammer/ Bryant |
2 x Cutler Hammer/ Bryant |
|
Westinghouse Type BR Series |
Westinghouse Type BR Series |
|
ITE Gould QP Series. |
ITE Gould QP Series. |
|
|
Max rating 30 A |
Max rating 25 A dual phase (ganged) |
| |
|
50 A split phase |
|
| AC fusing (Branch) |
8 x Cutler Hammer/ Bryant |
10 x Cutler Hammer/ Bryant/ |
|
Westinghouse Type BR Series |
Westinghouse Type BR Series |
|
ITE Gould QP Series. |
ITE Gould QP Series. |
|
|
Max rating 20 A |
Max rating 20 A |
|
| DC fusing |
11 x Littelfuse Type 257 (or equivalent). |
|
| |
Max rating 20 A |
|
|
| Operating temperature range |
14 °F to 140 °F (-10 °C to 60 °C) |
|
|
| Dimensions |
|
|
|
| Opening (stand alone) (H x W x D) |
8 x 12 x 3 7/16” (203 x 305 x 87 mm) |
|
| Opening (with converter) (H x W x D) |
12 1/8 x 12 x 4 3/4” (308 x 305 x 121 mm) |
|
| Face dimensions - Panel & Converter (cover on) |
13 1/16 x 13 15/16” (332 x 354 mm) |
|
| Face dimensions - Panel only (cover on) |
13 1/16 x 8 13/16” (332 x 224 mm) |
|
|
| Weight |
3.5 lb ( (1.59 kg) |
|
|
| Part numbers |
|
|
|
| OEM 4 pack |
810-0030-00 |
810-0050-00 |
|
| Aftermarket/Service single pack |
810-0030-10 |
810-0050-10 |
|
|
|
|
|
|
|
|
|
| Regulatory Approvals |
|
|
|
| UL458 (Panel board designed to meet UL67 when installed with converter) CSA C22.2 No. 107.1, FCC part 15B (Class B), ICES-0003 (Class B) |
| Note: Specifications subject to change without notice. |
|
|