Electrical Specifications |
|
|
AC input/output voltage |
|
120/240 VAC +/-10% at 60 Hz |
|
|
Continuous power (at 25° C) |
|
3900 VA as a step down / step up transformer or balancing transformer |
|
|
Idle consumption (typical at full voltage) |
|
12 watts |
|
|
Insertion loss |
|
Less that 4 VAC at 3900 VA |
|
|
Input/output AC breaker rating |
|
25 A 2 pole Square-D QOU Branch Circuit Rated/10,000 AIC |
|
|
General Specifications |
|
|
Hookup wire size |
|
14 AWG to 2 AWG |
|
|
Hookup access |
|
3/4" and 1" knockouts |
|
|
Enclosure type |
|
Indoor, ventilated, steel chassis with powdercoast finish |
|
|
Dimensions (H x W x D) |
|
6.3 x 21.0 x 7.0" (16 x 53.3 x 17.8 cm) |
|
|
Weight |
|
39.4 lb (17.9 kg) |
|
|
Warranty |
|
Two years |
|
|
Part number |
|
T240 |
|
|
Regulatory Approvals |
|
|
UL approved to standards UL 1741 - 1st Edition |
|
|
cUL approved to Canadian standard CAN/CSA C22.2 No. 107.1-95 |
|
|
|
Note: Specifications subject to change without notice. |