Specifications |
|
|
Current ratings |
|
100 A: 100 A continuous, 400 A peak |
|
|
|
|
250 A: 250 A continuous, 1200 A peak |
|
|
Voltage range |
|
7-33 V (24 V assumed if > 18.0 V) |
|
|
Low voltage disconnect range |
|
12.8-13.2 V (x2 for 24 V) |
|
|
Connect voltage range |
|
13.1-13.5 V (x2 for 24 V) |
|
|
High voltage disconnect range |
|
14-16 V (x2 for 24 V) |
|
|
Idle power consumed |
|
0.2-0.35 W at 12 V, 0.4-0.7 W at 24 V |
|
|
Connected power |
|
100 A/2 Bank 5.4 W @ 12 V, 5.8 W @ 24 V |
|
|
|
|
100 A/3 Bank 10.4 W @ 12 V, 10.8 W @ 24 V |
|
|
|
|
250 A/3 Bank 3.46 W @ 12 V, 5.43 W @ 24 V |
|
|
|
|
250 A/2 Bank 2.24 W @ 12 V, 3.69 W @ 24 V |
|
|
Indicator lights |
|
Disabled: Yellow |
|
|
|
|
Connected: Green |
|
|
|
|
High Voltage Disconnect: Red |
|
|
|
|
Wait for Reconnect: Flashing Red |
|
|
External control |
|
User supplied momentary on/off switch |
|
|
Operating temperature range |
|
-28.9° C to 48.9° C (100 A)
-40° C to 85° C (250 A) |
|
|
Remote panel (optional) |
|
Flush mount, splashproof front, 25' cable included
Dim: Flush Mount (2.25" H x 3.65" W x 0.75" D)
Cut-out (3" W x 1.625" H) |
|
|
Dimensions (H x W x D) |
|
100 A: 6.3 x 7.4 x 3.6" |
|
|
|
|
250 A: 7.6 x 7.4 x 3.2" |
|
|
Warranty |
|
One year |
|
|
Part number |
|
84-2051-02 (100 A with 2 battery banks) |
|
|
|
|
84-2051-03 (100 A with 3 battery banks) |
|
|
|
|
84-2094-01 (250 A with 2 battery banks) |
|
|
|
|
84-2094-03 (250A with 3 battery banks) |
|
|
|
|
84-2053-00 (Remote with 25' cable) |
|
|
|
Note: Specifications subject to change without notice. |